Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rambo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/agsgnnfb/public_html/glorioustronics.com/wp-includes/functions.php on line 6121
Heat Index Meter [WBGT-101] - Green PCB Tronics Co.,Ltd

Heat Index Meter [WBGT-101]

Heat Index Meter [WBGT-101]

wbgt101

(not CE conformed)

  • Wet Bulb Globe Temperature (WBGT) is commonly used as a guidance for environmental heat stress to prevent heat stroke during physical exercise or while at work.
  • WBGT as a measurement method to determine heat stress given to human body at work in thermally harsh environment is specified in ISO 7243 under the title; Hot Process & Environments – Estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature).
  • Below chart of WBGT-index shows the criterion of heat stress warning specified by Japan Athletic Society in order to prevent heat stroke:
    WBGT[°C] Types of warning and required rest
    Below 21 Safe (needs occasional supply of water)
    21 – 25 Note (needs immediate supply of water)
    25 – 28 Caution (needs to take rest)
    28 – 31 Warning (Stop active physical exercise)
    Above 31 Dangerous (Cancel physical exercise)
  • Maximum 1,000 sets of data can be stored, and continuous measurement by automatic sampling is possible.
  • Measuring result data can be printed out by the optional printer.

Specifications

Type and model name WBGT-101 Heat Index Meter
Measurement data
  • WBGT, Temperature, Humidity, Wet bulb temp. and Glob temp.
  • WBGT data can be switched Outdoor or Indoor.
Measuring range
WBGT : 0 – 50°C
Temperature : 0 – 50°C
Wet bulb temp. : 0 – 50°C
Humidity : 10 – 90%RH
Glob temp. : 0 – 50°C
Accuracy
WBGT : ±1.0°C (at 1°C)
Temperature : ±0.5°C (at 1°C, without radiation effect)
: ±1.0°C (at 1°C, with radiation at ±20°C)
Humidity : ±3% (at 20-80%RH)
Glob temp. : ±0.5°C (at 1°C)
Ambient condition
Ambient temperature : 0 – 40°C
Radiation temperature : 0 – 50°C
Stored data 1,000 sets
Sampling interval 1 – 99 minute
External I/O RS-232C for printer…1 ch.
Power source AM-3 : 1.5V dry cell 4pcs.
Accessories
1.5V dry cell ………………………………………. 4 pcs.
Tripod ………………………………………. 1 pce
Cramp head ………………………………………. 1 pce
Measuring part ………………………………………. 1 set
Hard case ………………………………………. 1 pce
Operating manual ………………………………………. 1 copy