4-20 mA Controller/Alarm/Indicator
Model No:CT-2012 24V out
Description: |
4-20 mA Controller/Alarm/Indicator Model : CT-2012 * Input : 4-20 mA DC, linear. * User can default the desired display value between -1999 to 9999 (decimal point can be selected to DP1, DP2, DP3) and all the preset data will be saved into the memory circuit permanently. * When CT-2012 cooperate LUTRON’s 4 to 20 mA transmitters, whole system will become the high performance Controller/Alarm/Indicator for following measuring functions : Humidity, Light, pH, Dissolved Oxygen, Conductivity, Vibration, Pressure, Sound, Temperature, RPM, Hz, Load cell (Weight, Force), Potential (Angle, Level). ACV, ACA, DCV, DCA, WATT…. * Control output: 2 points (COM, NO). * Alarm output: 2 points (COM, NO). * DC 24V power supply output. * RS232/USB computer interface. * Power : 90 ACV – 264 ACV, 50/60 Hz. * DIN size : 96 x 48 mm. Depth : 107 mm. |
RPM CONTROLLER/MONITOR
Model No:PDT-2250
Description: |
RPM CONTROLLER/MONITOR Model : PDT-2250 * 5 to 100,000 RPM (0.1rpm, <1,000 rpm). * Control setting, Hi/Lo alarm setting. * Control relay output, alarm relay output. * Power : 90 ACV to 264 ACV, 50/60 Hz. * RS-232 computer interface. * DIN size : 96 x 48 mm. Depth : 107 mm. * Optional proximity sensor PX-01. * Optional photo sensor PI-06. |
PANEL HUMIDITY/TEMP. METER
Model No:PHT-3109
Description: |
PANEL HUMIDITY/TEMP. METER Model : PHT-3109 * Humidity : 10 to 95 %RH. * Temperature : 0 to 60 oC. * Resolution : 0.1 %RH, 0.1 degree. * Humidity control setting, Temp. control setting. * Humidity control relay output, Temp. control relay output. * Power : 90 ACV to 264 ACV, 50/60 Hz. * RS-232 computer interface. * DIN size : 96 x 48 mm. Depth : 107 mm. * Accessory included : Humidity/Temp. probe. |
PH CONTROLLER/MONITOR
Model No:PPH-2108
Description: |
PH CONTROLLER/MONITOR Model : PPH-2108 * 0 to 14 pH x 0.01 pH. * ATC (automatic temperature compensation). * pH control setting, Temp. control setting. * pH control relay output, Temp. control relay output. * Power : 90 ACV to 264 ACV, 50/60 Hz. * RS-232 computer interface. * DIN size : 96 x 48 mm. Depth : 107 mm. * Optional pH electrodes, ATC probe. |
RS232 CONTROLLER/MONITOR
Model No:PRS-2321
Description: |
RS232 CONTROLLER/MONITOR Model : PRS-2321 * Cooperate the LUTRON instruments (build in the RS232 interface), the panel meter will show all the measuring value. * U1 control setting, U2 control setting. * U1 control relay output, U2 control relay output. * U1, U2, U3 display. * Power : 90 ACV to 264 ACV, 50/60 Hz. * RS-232 computer interface. * Interface cable UPCB-03 is included. * DIN size : 96 x 48 mm. Depth : 107 mm. |
2 WIRES PRESSURE TRANSMITTER
Model No:TR-PS2W
Description: |
2 WIRES PRESSURE TRANSMITTER Model : TR-PS2W-xxBAR * Range : 2, 5, 10, 20, 50, 100, 400 BAR. * Output : 4 to 20 mA DC, 4 mA = 0 pressure, 20 mA = full scale pressure. * 2 wires, both for signal and power supply. * Precision ceramic type pressure sensor. * External zero and span adjustment. * Output with socket, easy replacement. * Allow high cable load resistance, transmitter can install far away from the controller/incator. * Protection for the reverse wires connecting. * TR-PS2W can cooperate the “4-20 mA Controller/Alarm/Indicator” CT-2012, then become a pressure controller and the indicating system. The user can control and monitor the pressure value from far away. |
2 WIRES HUMIDITY TRANSMITTER
Model No:TR-RH2W
Description: |
2 WIRES HUMIDITY TRANSMITTER Model : TR-RH2W * Range : 10 %RH to 95 %RH. * Output : 4 to 20 mA DC, 5.6 mA = 10 %RH, 12 mA = 50 %RH, 16 mA = 75 %RH, 19 mA = 95 %RH * 2 wires, both for signal and power supply. * Precision capacitance type humidity sensor. * External zero and span adjustment. * Allow high cable load resistance, transmitter can install far away from the controller/incator. * Protection for the reverse wires connecting. * TR-RH2W can cooperate the ” 4-20 mA Controller/Alarm/Indicator ” CT-2002-MA, then become a humidity controller and the indicating system. The user can control and monitor the humidity value from far away. |
Model : PVA-6067
FEATURES
* Professional Apparent power meter with standard DIN
case ( 96 x 48 mm ) and Control/Alarm function.
* Microprocessor circuit ensures high accuracy and provide special functions and features.
* Large red LED display, high brightness and easy to read.
* Measurement range ( no cooperate the external CT and the PT ) :
VA : 0 to 6,000 VA.
* Input signal ( without PT, CT ) : ACV : 0 to 600 ACV, 40 to 400 Hz. ACA : 0 to 10 A, 40 to 400 Hz.
* Current input can cooperate the external CT ( current transformer ) such as CT 1000/5A, CT 100/5A …to expend the measurement range. The CT range can be adjusted with default.
* Voltage input can cooperate the external PT ( voltage
transformer ) to expend the measurement range. The
PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Control Relay will make action when the reading value reach to control value.
* Alarm Relay will make action when the reading value reach to high/low alarm value.
* Hysteresis value setting for control and alarm function.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.
* Option data acquisition software.
RS232 CONTROLLER/MONITOR Model :PRS-2321
FEATURES
* RS232 input, can cooperate full line LUTRON instruments ( build RS232 output )
be used as a professional controller/monitor.
* It can control max. two reading value ( Unit 1 or Unit 2 value ) if the LUTRON
RS232 meter build two displays.
* It can show max. three reading value ( Unit 1 or Unit 2 or Unit 3 value ) if the LUTRON RS232 meter build in three displays.
* Professional monitor and controller.
* Build in Unit 1 control relay and the Unit 2 control relay.
* Relay will be make action ( On/Off ) when the reading value reach high limit or low limit value.
* Offset value setting.
* Hysteresis value setting for high and low alarm.
* Large red LED display, high brightness and easy to read.
* Microprocessor circuit ensures high accuracy and provides special functions and features.
* Standard 96 X 48 mm DIN case.
IR TEMPERATURE CONTROLLER/MONITOR Model : PIR-9959
Infrared temperature
FEATURES
* Input : 4-20 mA DC, * Display resolution setting :
4 mA = 0.0 ℃ (32.0 ℉) or 4 mA = 0 ℃ (32 ℉) 1 degree or 0.1 degree
20 mA = 400.0 ℃ (752.0 ℉) or 20 mA = 400 ℃ (752 ℉) Main * Low limit of range adjustment :
* User can default the Temp. unit to ℃ or ℉. Internal 4 mA = 0.0 for ℃.
* User can default the resolution of Temp. value to 0.1 Function 4 mA = 32.0 for ℉.
degree or 1 degree. Selection * High limit of range adjustment :
* When PIR-9959 cooperate LUTRON’s 4 to 20 mA 20 mA = 400.0 for ℃.
IR Temp. transmitters ( TR-IR2W ) 20 mA = 752.0 for ℉.
, whole system will become the * Alarm value adjustment :
high performance Controller/Alarm/Indicator High Alarm or Low alarm.
of no contact IR Temp. measurement system. * Control value adjustment
* Easy to adjust the function factors by push button High control or Low control.
on the front panel. * Control hysteresis value setting.
* Control output : 2 points ( COM, NO ). * Alarm hysteresis value setting.
* Alarm output : 2 points ( COM, NO ). * Filter value of display reading
* Control Relay will make action when the reading value * Offset adjustment.
reach to control value. * Gain adjustment.
* Hysteresis value setting for control and alarm function. * Temp. unit ( C, F )
* Large red LED display, high brightness and easy to read. Default of internal function :
* Microprocessor circuit ensures high accuracy and Without advice previously, the function
provides special functions and features. of PIR-9959 will preset :
* DC 24V power supply output, used for the power supply * 4 mA = 0.0, 20 mA = 400.0
external IR Temp. transmitter. * High control mode.
* RS232/USB computer interface. * High alarm mode.
* Power : 90 ACV – 260 ACV, 50/60 Hz. * Temp. unit is ℃.
* Standard 96 X 48 mm DIN case. Fro
DCV CONTROLLER/MONITOR Model : PDV-6070
FEATURES
* Professional DCV meter with standard DIN case ( 96 x Sampling Time Approx. 0.5 second.
48 mm) and Control / Alarm Function. Over input ” – – – – ” mark indication.
* Microprocessor circuit ensures high accuracy and Front Panel Measuring value from the actual PV.
provide special functions and features . Function Control set :
* Measurement DC Voltage : Selection point value adjustment from the SV.
200 mV x 0.1 mV / 2 V x 0.001 V / 20 V x 0.01 V / Alarm set :
200 V x 0.1 V / 600 V x 1 V . point value adjustment from the SV .
* Measurement range can be adjusted by jumper . Zero Automatic adjustment.
* Input Impedance 10 MΩ. Adjustment
* Large red LED display ,high brightness and easy to read. Data Output RS232 / USB PC Computer interface.
* Control output : 2 point ( COM,NO ). * Connect the optional RS232 cable ,
* Alarm output : 2 point ( COM,NO ). UPCB – 02 will get the RS232 plug.
* Control Relay will make action when the reading value * Connect the optional USB cable,
reach to control value. USB – 01 will get the USB plug.
* Hysteresis value setting for control and alarm function . Operating 0 to 50 ℃.
* RS232 / USB Computer interface . Temperature
* Power : 90 ACV – 260 ACV , 50 / 60Hz . Operating Less than 80% R.H.
* Option data acquisition software . Humidity
DC Current CONTROLLER/MONITOR Model : PDA-6071
FEATURES
* Professional DC Current meter with standard DIN Over input ” – – – – ” mark indication.
case ( 96 x 48 mm) and Control / Alarm Function. Front Panel Measuring value from the actual PV.
* Microprocessor circuit ensures high accuracy and Function Control set :
provide special functions and features . Selection point value adjustment from the SV.
* Measurement DC Current : Alarm set :
200 uA x 0.1 uA / 2 mA x 0.001 mA / 20 mA x 0.01 mA point value adjustment from the SV .
200 mA x 0.1 mA / 2 A x 0.001 A / 10 A x 0.01 A . Zero Automatic adjustment.
* Measurement range can be adjusted by jumper . Adjustment
* Fuse overload protection for all ranges. Sampling Time Approx. 0.5 second.
* Large red LED display ,high brightness and easy to read. Data Output RS232 / USB PC Computer interface.
* Control output : 2 point ( COM,NO ). * Connect the optional RS232 cable ,
* Alarm output : 2 point ( COM,NO ). UPCB – 02 will get the RS232 plug.
* Control Relay will make action when the reading value * Connect the optional USB cable,
reach to control value. USB – 01 will get the USB plug.
* Hysteresis value setting for control and alarm function . Operating 0 to 50 ℃.
* RS232 / USB Computer interface . Temperature
* Power : 90 ACV – 260 ACV , 50 / 60Hz .