Controllers (Alarm/Monitor), full line

4-20 mA Controller/Alarm/Indicator

Model No:CT-2012 24V out

22

Description:
4-20 mA Controller/Alarm/Indicator
Model : CT-2012
* Input : 4-20 mA DC, linear.
* User can default the desired display value between -1999 to 9999
(decimal point can be selected to DP1, DP2, DP3) and all the preset
data will be saved into the memory circuit permanently.
* When CT-2012 cooperate LUTRON’s 4 to 20 mA transmitters, whole
system will become the high performance Controller/Alarm/Indicator
for following measuring functions : Humidity, Light, pH, Dissolved
Oxygen, Conductivity, Vibration, Pressure, Sound, Temperature, RPM,
Hz, Load cell (Weight, Force), Potential (Angle, Level). ACV, ACA, DCV,
DCA, WATT….
* Control output: 2 points (COM, NO).
* Alarm output: 2 points (COM, NO).
* DC 24V power supply output.
* RS232/USB computer interface.
* Power : 90 ACV – 264 ACV, 50/60 Hz.
* DIN size : 96 x 48 mm. Depth : 107 mm.

RPM CONTROLLER/MONITOR

Model No:PDT-2250

23

Description:
RPM CONTROLLER/MONITOR
Model : PDT-2250
* 5 to 100,000 RPM (0.1rpm, <1,000 rpm).
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional proximity sensor PX-01.
* Optional photo sensor PI-06.

PANEL HUMIDITY/TEMP. METER

Model No:PHT-3109

1

Description:
PANEL HUMIDITY/TEMP. METER
Model : PHT-3109
* Humidity : 10 to 95 %RH.
* Temperature : 0 to 60 oC.
* Resolution : 0.1 %RH, 0.1 degree.
* Humidity control setting, Temp. control setting.
* Humidity control relay output, Temp. control relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Accessory included : Humidity/Temp. probe.

PH CONTROLLER/MONITOR

Model No:PPH-2108

3

Description:
PH CONTROLLER/MONITOR
Model : PPH-2108
* 0 to 14 pH x 0.01 pH.
* ATC (automatic temperature compensation).
* pH control setting, Temp. control setting.
* pH control relay output, Temp. control relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional pH electrodes, ATC probe.

RS232 CONTROLLER/MONITOR

Model No:PRS-2321

4

Description:
RS232 CONTROLLER/MONITOR
Model : PRS-2321
* Cooperate the LUTRON instruments (build in the RS232 interface), the panel meter will show all the
measuring value.
* U1 control setting, U2 control setting.
* U1 control relay output, U2 control relay output.
* U1, U2, U3 display.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* Interface cable UPCB-03 is included.
* DIN size : 96 x 48 mm. Depth : 107 mm.

2 WIRES PRESSURE TRANSMITTER

Model No:TR-PS2W

5

Description:
2 WIRES PRESSURE TRANSMITTER
Model : TR-PS2W-xxBAR
* Range : 2, 5, 10, 20, 50, 100, 400 BAR.
* Output : 4 to 20 mA DC,
4 mA = 0 pressure,
20 mA = full scale pressure.
* 2 wires, both for signal and power supply.
* Precision ceramic type pressure sensor.
* External zero and span adjustment.
* Output with socket, easy replacement.
* Allow high cable load resistance, transmitter can install far away from the controller/incator.
* Protection for the reverse wires connecting.
* TR-PS2W can cooperate the “4-20 mA Controller/Alarm/Indicator” CT-2012, then become a
pressure controller and the indicating system. The user can control and monitor the pressure value
from far away.

2 WIRES HUMIDITY TRANSMITTER

Model No:TR-RH2W

6

Description:
2 WIRES HUMIDITY TRANSMITTER
Model : TR-RH2W
* Range : 10 %RH to 95 %RH.
* Output : 4 to 20 mA DC, 5.6 mA = 10 %RH, 12 mA = 50 %RH, 16 mA = 75 %RH, 19 mA = 95 %RH
* 2 wires, both for signal and power supply.
* Precision capacitance type humidity sensor.
* External zero and span adjustment.
* Allow high cable load resistance, transmitter can install far away from the controller/incator.
* Protection for the reverse wires connecting.
* TR-RH2W can cooperate the ” 4-20 mA Controller/Alarm/Indicator ” CT-2002-MA, then become a
humidity controller and the indicating system. The user can control and monitor the humidity value
from far away.

Model : PVA-6067

PVA-6067

FEATURES

* Professional Apparent power meter with standard DIN

case ( 96 x  48 mm ) and Control/Alarm function.

* Microprocessor circuit ensures high accuracy and provide special functions and features.

* Large red LED display, high brightness and easy to read.

* Measurement range ( no cooperate the external CT and the PT ) :

VA : 0 to 6,000 VA.

* Input signal ( without PT, CT ) : ACV : 0 to 600 ACV, 40 to 400 Hz. ACA : 0 to 10 A, 40 to 400 Hz.

* Current input can cooperate the external CT ( current transformer ) such as CT 1000/5A, CT 100/5A …to expend the measurement range. The CT range can be adjusted with default.

* Voltage input can cooperate the external PT ( voltage

transformer ) to expend the measurement range. The

PT range can be adjusted with default.

* Control setting, Hi/Lo alarm setting.

* Control relay output, alarm relay output.

* Control Relay will make action when the reading value reach to control value.

* Alarm Relay will make action when the reading value reach to high/low alarm value.

* Hysteresis value setting for control and alarm function.

* Power : 90 ACV to 264 ACV, 50/60 Hz.

* RS232/USB computer interface.

* Option data acquisition software.


RS232 CONTROLLER/MONITOR Model :PRS-2321

PRS-2321

FEATURES

* RS232 input, can cooperate full line LUTRON instruments ( build RS232 output )

be used as a professional controller/monitor.

* It can control max. two reading value ( Unit 1 or Unit 2 value ) if the LUTRON

RS232 meter build two displays.

* It can show max. three reading value ( Unit 1 or Unit 2 or Unit 3 value ) if the LUTRON RS232 meter build in three displays.

* Professional monitor and controller.

* Build in Unit 1 control relay and the Unit 2 control relay.

* Relay will be make action ( On/Off ) when the reading value reach high limit or low limit value.

* Offset value setting.

* Hysteresis value setting for high and low alarm.

* Large red LED display, high brightness and easy to read.

* Microprocessor circuit ensures high accuracy and provides special functions and features.

* Standard 96 X 48 mm DIN case.


IR TEMPERATURE CONTROLLER/MONITOR Model : PIR-9959

Infrared temperature

PIR-9959 PIR-9959

FEATURES

* Input : 4-20 mA DC, * Display resolution setting :

4 mA = 0.0 ℃ (32.0 ℉) or 4 mA = 0 ℃ (32 ℉) 1 degree or 0.1 degree

20 mA = 400.0 ℃ (752.0 ℉) or 20 mA = 400 ℃ (752 ℉) Main * Low limit of range adjustment :

* User can default the Temp. unit to ℃ or ℉. Internal 4 mA = 0.0 for ℃.

* User can default the resolution of Temp. value to 0.1 Function 4 mA = 32.0 for ℉.

degree or 1 degree. Selection * High limit of range adjustment :

* When PIR-9959 cooperate LUTRON’s 4 to 20 mA 20 mA = 400.0 for ℃.

IR Temp. transmitters ( TR-IR2W ) 20 mA = 752.0 for ℉.

, whole system will become the * Alarm value adjustment :

high performance Controller/Alarm/Indicator High Alarm or Low alarm.

of no contact IR Temp. measurement system. * Control value adjustment

* Easy to adjust the function factors by push button High control or Low control.

on the front panel. * Control hysteresis value setting.

* Control output : 2 points ( COM, NO ). * Alarm hysteresis value setting.

* Alarm output : 2 points ( COM, NO ). * Filter value of display reading

* Control Relay will make action when the reading value * Offset adjustment.

reach to control value. * Gain adjustment.

* Hysteresis value setting for control and alarm function. * Temp. unit ( C, F )

* Large red LED display, high brightness and easy to read. Default of internal function :

* Microprocessor circuit ensures high accuracy and Without advice previously, the function

provides special functions and features. of PIR-9959 will preset :

* DC 24V power supply output, used for the power supply * 4 mA = 0.0, 20 mA = 400.0

external IR Temp. transmitter. * High control mode.

* RS232/USB computer interface. * High alarm mode.

* Power : 90 ACV – 260 ACV, 50/60 Hz. * Temp. unit is ℃.

* Standard 96 X 48 mm DIN case. Fro


DCV CONTROLLER/MONITOR  Model : PDV-6070

PDV-6070

FEATURES

* Professional DCV meter with standard DIN case ( 96 x Sampling Time Approx. 0.5 second.

48 mm) and Control / Alarm Function. Over input ” – – – – ” mark indication.

* Microprocessor circuit ensures high accuracy and Front Panel Measuring value from the actual PV.

provide special functions and features . Function Control set :

* Measurement DC Voltage : Selection point value adjustment from the SV.

200 mV x 0.1 mV / 2 V x 0.001 V / 20 V x 0.01 V / Alarm set :

200 V x 0.1 V / 600 V x 1 V . point value adjustment from the SV .

* Measurement range can be adjusted by jumper . Zero Automatic adjustment.

* Input Impedance 10 MΩ. Adjustment

* Large red LED display ,high brightness and easy to read. Data Output RS232 / USB PC Computer interface.

* Control output : 2 point ( COM,NO ). * Connect the optional RS232 cable ,

* Alarm output : 2 point ( COM,NO ). UPCB – 02 will get the RS232 plug.

* Control Relay will make action when the reading value * Connect the optional USB cable,

reach to control value. USB – 01 will get the USB plug.

* Hysteresis value setting for control and alarm function . Operating 0 to 50 .

* RS232 / USB Computer interface . Temperature

* Power : 90 ACV – 260 ACV , 50 / 60Hz . Operating Less than 80% R.H.

* Option data acquisition software . Humidity


DC Current CONTROLLER/MONITOR Model : PDA-6071

PDA-6071

FEATURES

* Professional DC Current meter with standard DIN Over input ” – – – – ” mark indication.

case ( 96 x 48 mm) and Control / Alarm Function. Front Panel Measuring value from the actual PV.

* Microprocessor circuit ensures high accuracy and Function Control set :

provide special functions and features . Selection point value adjustment from the SV.

* Measurement DC Current : Alarm set :

200 uA x 0.1 uA / 2 mA x 0.001 mA / 20 mA x 0.01 mA point value adjustment from the SV .

200 mA x 0.1 mA / 2 A x 0.001 A / 10 A x 0.01 A . Zero Automatic adjustment.

* Measurement range can be adjusted by jumper . Adjustment

* Fuse overload protection for all ranges. Sampling Time Approx. 0.5 second.

* Large red LED display ,high brightness and easy to read. Data Output RS232 / USB PC Computer interface.

* Control output : 2 point ( COM,NO ). * Connect the optional RS232 cable ,

* Alarm output : 2 point ( COM,NO ). UPCB – 02 will get the RS232 plug.

* Control Relay will make action when the reading value * Connect the optional USB cable,

reach to control value. USB – 01 will get the USB plug.

* Hysteresis value setting for control and alarm function . Operating 0 to 50 .

* RS232 / USB Computer interface . Temperature

* Power : 90 ACV – 260 ACV , 50 / 60Hz .